GENERAL |
| |
|
| Approvals |
UL, CE |
| Regeneration Method |
Automatic, demand |
| Maximum dew point |
-40˚ F/C |
|
| |
ENCLOSURE |
| |
|
| Type |
Hoffman® POLYPRO® Polyester Type 4X |
| Cover Attachment |
Hinged, lockable |
| Protection |
IP66, NEMA 4X |
| Dimensions |
15.31″ × 18.06 ” × 9.25 ” (389mm × 459mm × 235mm) |
| |
|
| Entries |
|
| 1 x 0.88″ (22mm) |
entry for supply power
|
| 2 x 0.63″ (16mm) |
entry for dry pressurized air and condensate discharge |
| |
|
| Weight |
24 lbs (10.9 kg) |
| Mounting |
Wall, post/pole or shelf mounted |
|
| |
POWER |
| |
|
| Supply |
±20-75 VDC |
| Maximum current |
1.0 Amps at 100 V |
| Power usage |
40 W typical, 100 W max |
|
| |
OUTPUT |
| |
|
| Flow rate |
25.4 scfh (12 lpm) |
| Maximum pressure |
7.5 psig (517mbar) |
| Internal safety relief valve |
8 psig (552mbar) |
| Discharge port |
1/8″ NPT /
3/8″ or 1/4″ hose barb (both included) |
| Display units |
SI (millibars); English (psig), default |
|
| |
CONTROL |
| |
|
| Protocols |
HTTP (Web Interface), SNMP, UDP, TFTP |
| Maximum pressure |
Confi gurable Range: 0.20 psig – 7.5 psig (14mbar – 517mbar), Default: 0.50 psig (34.5mbar) |
| Minimum pressure |
Confi gurable Range: 0.10 psig – 7.4 psig (7mbar – 510mbar), Default: 0.30 psig (21mbar) |
| Low pressure alarm level |
User Configurable, Default: 0.15 psig (10mbar) |
| High pressure alarm level |
User Configurable, Default 1.5 psig (103.5mbar) |
| Alarm relays |
Contact Type – Form C, SPDT, reverse acting
Ratings – 0.25 Amps @ 60 V
User configurable, Defaults:
- Alarm Relay 1: Summary Alarm
- Alarm Relay 2: Low Pressure Alarm
- Alarm Relay 3: Over Pressure Alarm
|
| Duty cycle alarm |
User configurable, Default: 50% |
| Master/Slave configuration |
User configurable, Default: Standard/Slave |
|
| |
ENVIRONMENTAL |
| |
|
| Operating temperature |
−40°F to 130°F (0°C to 55°C) |
| Storage temperature |
−40°F to 150°F (−40°C to 60°C) |
|
| |